Trauma with my Trumatic C3402

 
 
 
 
 
littlemac
 
Avatar
 
Subject:

Trauma with my Trumatic C3402

 · 
Posted: 07.01.2012  ·  #1
Hi Campers

I am having trouble with Trumatic C3402, it starts heats water and habitation, but after 30/40 mins cuts out showing red fail light.

If started again run for shrot period and fails again

any ideas

Ash


Leisure Tech Solutions
Craic'er
Avatar
Gender: n/a
Location: Dromore
Homepage: leisuretechnicalso…
Posts: 40
Registered: 09 / 2011
Subject:

C3402

 · 
Posted: 07.01.2012  ·  #2
HI Ash

Like all possible causes,, it could be a number of issues,, sounds like over heating initially,

Temp sensing is taken from the wall switch, or if fitted, a room temp sensor,, check that these are clear from obstruction and away from another heat source.

Gas,, use red propane at this time of year, as the blue butane may not vapourise enough gas to keep supplying the boiler,,

I would imagine you have the heat set fairly high with low ambient temp,

check the four take of ducts on the underneath the boiler, as one or two of these may have become disconnected raising the temperature around the boiler..

Also if you have the temperature setting set to max, just bring it back a little and see if the unit will run for a longer duration..